Rapid Under-2-Minute Application
Intuitive belt-and-clip system engineered specifically for fast deployment by emergency responders, paramedics, and first aiders — even under extreme field conditions with limited lighting or space.
Malaysian-designed, clinically validated, and award-winning — the RhinoQure™ bridges the gap between emergency field deployment and uninterrupted operating theatre access.
Major pelvic fractures — from road traffic accidents, falls from height, industrial or combat trauma, natural disasters, or obstetric emergencies — are among the most lethal injuries encountered in emergency medicine. The primary cause of death is silent internal retroperitoneal hemorrhage: massive bleeding into the pelvic cavity that is invisible from the outside and rapidly fatal if not arrested.
Conventional pelvic binders address the bleeding but create a critical secondary problem: they are bulky, obstructive, and must be dangerously removed before surgery — causing re-bleeding, delaying operating room preparation, and placing already-critical patients at heightened risk during the removal process.
Standard binders also impede ambulance transport positioning, hinder neurological assessment of lower limbs, and block catheter insertion and imaging — creating a cascade of compromises in the golden hour of trauma care.
An external pelvic and lower-limb stabilization binder that equips in under 2 minutes and delivers a controlled tamponade effect to arrest pelvic bleeding — while its patented foldable design maintains full surgical access without removal throughout the entire care pathway.
Recognized at Malaysia's premier platform for applied research and medical innovation — validating RhinoQure™'s clinical significance and engineering novelty on a national stage.
RhinoQure™ was developed by Prof. Dr. Ismail bin Hj. Saiboon and his dedicated research team at UKM — bringing together decades of emergency medicine expertise and clinical insight to engineer a device that works in the field, in the ambulance, and in the operating theatre without compromise.
From the incident scene to the operating table — RhinoQure™ maintains its clinical advantage through every transition of care.
Intuitive belt-and-clip system engineered specifically for fast deployment by emergency responders, paramedics, and first aiders — even under extreme field conditions with limited lighting or space.
Detachable port roof and fold-down working ends allow laparotomy, angio-embolization, pelvic external fixation (ASIS access), and bladder catheterization without removing the binder — eliminating re-bleeding risk during the surgical transition.
Modular Left and Right Leg Extenders stabilize concurrent femur or tibia/fibula fractures — addressing the most common co-injuries of major pelvic trauma in a single unified device system.
Rapid anterior Greater Trochanter (GT) measurement using the included Green (A), Yellow (B), and Red (C) Measuring Belt — ensuring the correct binder size is selected in seconds, even under field stress.
Supports an air-cushion pressure gauge system (≤33 kPa) for precise, monitored pelvic compression — allowing clinicians to titrate compression force and document applied pressure for clinical records.
X-ray and CT scan transparent materials allow full imaging without removal. Durable, reusable, skin-friendly biocompatibility-tested construction. Compact profile designed for tight ambulance compartments and rapid-deployment field bags.
Every component of the RhinoQure™ system is purpose-engineered. Each deployment step follows a clinical protocol optimized for speed and accuracy.
The primary structural frame incorporating the pelvic compression mechanism. The Red Greater Trochanter Belt and Black Iliac-Crest Belt work in concert to deliver controlled, bilateral pelvic compression with the patented foldable surgical-access port integrated into the frame.
A dedicated sizing tool featuring three color-coded zones — Green (A), Yellow (B), and Red (C) — calibrated to anterior Greater Trochanter circumference measurement, enabling paramedics to select the correct main frame size in seconds without estimation.
Modular attachment for the left lower limb. Provides immobilization for concurrent femoral shaft, distal femur, or tibia/fibula fractures on the left side — attaching directly to the main frame without additional fasteners.
Modular attachment for the right lower limb. Mirrors the left extender's design and function, providing complete bilateral lower-limb stabilization as a fully integrated extension of the RhinoQure™ system.
Use the Color-Coded Measuring Belt to perform a rapid anterior Greater Trochanter circumference measurement. Select the corresponding main frame size (Green A / Yellow B / Red C) based on the measured zone. This takes under 20 seconds with a trained responder.
Thread the RhinoQure™ main frame underneath the patient via the scoop-stretcher log-roll technique — maintaining spinal and pelvic precautions throughout. Position the device centered on the greater trochanters, not the iliac crests, to ensure correct anatomical alignment.
Fasten the Red GT-Belt first, followed by the Black Iliac-Belt, applying firm bilateral compression to the pelvic ring. Attach leg extenders if lower-limb fractures are present. The tamponade effect is achieved immediately upon correct belt tensioning — under 2 minutes total.
Perform a systematic distal neurovascular assessment: check capillary refill, dorsal pedal pulses, sensation, and motor function bilaterally. Document findings and compression pressure (if pneumatic gauge attached). The patient may now be transported, imaged, or moved directly to the operating theatre without binder removal.
Watch the official product overview and clinical demonstration video — covering the complete deployment workflow, surgical-access features, and real-world emergency application scenarios.
Video not loading? Watch directly on YouTube →
RhinoQure™ is designed to perform across every level of Malaysia's emergency and healthcare system — from the ambulance to the operating theatre.
Primary deployment point for rapid pelvic stabilization of major trauma arrivals — from accident & emergency triage through to operating theatre preparation.
The foldable surgical-access port allows orthopaedic surgeons to perform pelvic external fixation and access ASIS landmarks without binder removal — maintaining hemostasis throughout.
Adopted by ASETS (Academy of Medicine Malaysia) for high-fidelity trauma simulation training — building clinical competency in pelvic fracture management across all specialties.
Compact design and rapid application protocol makes RhinoQure™ ideal for all ambulance fleets — including St. John Ambulance, Civil Defence (APM), and Fire & Rescue (JBPM) services.
Applicable in obstetric pelvic ring injuries — particularly postpartum symphyseal diastasis and traumatic pelvic ring disruption associated with complicated deliveries.
Rugged, compact, and field-deployable construction makes RhinoQure™ suitable for military field medic kits, HADR (Humanitarian Assistance & Disaster Relief) teams, and mass casualty incident response.